History — Alarms
← Manual
The Alarms history section is a searchable, paginated log of all alarm incidents recorded by the system. Each alarm groups the suspicious events that triggered it and shows who acknowledged it.
For live alarm management (the floating alarm window, Arm/Disarm controls), see the Overall Layout & Global Controls page. For configuring which events trigger alarms per device, see Devices — Device Alarms tab.
Page Structure
┌──────────────────────────────────────────────────────────────────────┐
│ Filter bar │
│ - "Filter Alarms" when no filters active │
│ - Active filters shown as deletable chips │
├────────────────────┬─────────────────────────────────────────────────┤
│ Toolbar (right) │ Alarm list │
│ - Refresh button │ One collapsible entry per alarm incident │
│ │ - Collapsed: timestamp, event count, acked by │
│ │ - Expanded: list of triggering events │
├────────────────────┴─────────────────────────────────────────────────┤
│ Event Detail panel (shown when a triggering event is selected) │
└──────────────────────────────────────────────────────────────────────┘
Filter Bar
Clicking the filter bar opens the Filter Alarms Dialog.
Filter Alarms Dialog
| Field | Description |
|---|---|
| Devices | Filter to alarms triggered by specific devices |
| Event Type | Filter to alarms involving specific event kinds |
| Time From | Lower time bound |
| Time To | Upper time bound |
Alarm List
Each alarm is shown as a collapsible accordion entry:
Collapsed — shows the alarm timestamp, event count chip (e.g. “3 Event(s)”), and an “Acknowledged by [user]” chip if the alarm was acknowledged.
Expanded — shows a stack of triggering event rows, each with:
- Event description (kind + source device)
- Event timestamp
Clicking a triggering event row opens the Event Detail Panel for that specific event (the same panel used in History — Events).
Live Alarm Floating Window
When an alarm is actively firing and has not been minimised, a draggable, resizable floating window appears over the entire UI. It cannot be blocked by other dialogs.
Window Controls
| Control | Description |
|---|---|
| Do Not Disturb toggle | Silences the alarm sound while the window stays visible |
| Dismiss | Hides the window; alarm remains active and the notification badge persists |
| Acknowledge | Marks the alarm as acknowledged; clears the active alarm state |
Triggering Events (inside the window)
Each triggering event is shown in an expandable accordion. Expanding an event loads associated camera feeds in a twin view showing:
- Live feed — current camera view
- Playback — seeked to the exact event timestamp
Arm / Disarm
The Arm/Disarm button in the app bar controls whether “trigger-when-armed” alarm configurations are active across all monitored devices.
| State | Behaviour on Click |
|---|---|
| Devices are armed | Disarm all |
| No devices armed | Arm all |
| Armed with bypassed devices | Opens a status popover; arm/disarm still available |
The button shows counts of armed vs total devices.
Related Concepts
- Alarms — conceptual overview of the alarm system
- Automation & Alarms — How They Work Together
- Devices — Device Alarms tab — configure alarm behaviour per device